Industrial Noise Control Products


Leading Manufacturers, Exporters and Wholesaler of Sound Proof Acoustic Enclosures, Industrial Acoustic Enclosure, room acoustic enclosure, Noise Test Chamber and Acoustic Silencer from Noida.

Price : 1,100.00 - 15,000.00 / Sq. Ft.
Get Best Price

MOQ : 1 Pees

Business Type Manufacturer, Supplier
Brand Name Envirotech Systems Limited
Size As Requirmets
Material Soundproof Meterial
Product Code N B -3
Port Noida
Payment Terms Other
Delivery Time With in 2-weeks

Preferred Buyer From

Location Worldwide

Envirotech is an Indian Acoustic Enclosure Manufacturer that provides solutions to noise problems. Acoustic enclosures are designed to suit both indoor and outdoor conditions and can be used for compressors, turbines, blowers, glass breakers, power plants, fin presses, punch presses, DG units, chillers, and more.

It meets all noise reduction requirements for DG installations from 5kva to 2,000kva.

 

 

Read More...


Yes! I am interested


Price : 600.00 / Square Feet
Get Best Price
Business Type Manufacturer, Supplier
Panel Thickness 100mm
Lock Spring Loaded Lock, Open Able from Both Sides
Infilled Material High Density Acoustical Material
Light & Electrical Electrical Wiring, Switch Board & Light to Maintain 300 Lux Inside the Enclosure
Noise Reduction Up to 50 dB (A)
Design Cad Drawing of Enclosure as per Actual Site Condition and Machine
Rain Protection Rain Water Protection Hood to Corner for Fresh Air Inlet Acoustic Louvers
Cut-outs Provided Cut-outs in Acoustic Panel for Pipe / Cable Entry or Any other Requirement.
Paint Two Coat Primer & Automotive Paint in Desired Shade
Ventilation Acoustically treated louvers on roof of Acoustic Enclosure for air inlet & exhaust

Click to view more

Preferred Buyer From

Location Worldwide

Acoustic Enclosures are specially designed enclosed units for equipment that has a high reverberation and noise level. We have different acoustic enclosures for different kind of units which cater to the specific need. This could vary from a power plant to diesel generator to turbine enclosures. Each enclosure is designed according to the specific requirements of the type of unit with the focus being on acoustic level control.

The acoustic enclosure has been designed to reduce the noise emitted into the environment. The noise levels are according to the industrial application CPCB norms and as per ISO 14001 standards.

Usage for :

  • DG Sets 1250/1500/1670KVA
  • Compressor
  • Gas Genet
  • Blower
  • Turbine
  • Heavy machines
  • Press Machine
  • Fin Press Machine
  • Conveyor
Read More...


Yes! I am interested


Price : 2,500.00 / Square Meter
Get Best Price
Business Type Manufacturer, Supplier
Wall Tile 600x600mm or 1200x1200mm
Ceiling Tile 600x600mm
Tile Perforation 3,4,5 mm or as per requirement
Infilled Material High Density Acoustical Material
Colour As per Requirement
Cut-outs Proper arrangement for cut-outs
Wiring Internal or External Electrical Wiring Arrangement
Mounting Addition Instrument Mounting Arrangement
Noise Reduction Up to 50dB (A)
Light Proper Light Arrangement to Maintain 300 Lux Inside

Click to view more

Preferred Buyer From

Location Worldwide

Room acoustics provide noise control with acoustic linings within the walls and ceiling. Accompaniments include acoustic door and soundproof glass. These materials weigh in around 48/64 96kg/m3 which confirms to IS 8183 and BS 476 Part II. The tissue fibers are laminated and covered with GI/AI with perforated sheets (45% perforation). The tiles are pre-coated with micro-perforated clip-in’s which also gives it an edge aesthetically. Air ventilation is also availed to provide maximum airflow to cool and prevent over-heating.

Usage for :

  • Engine testing room
  • DG rooms
  • Home theatre
Read More...


Yes! I am interested


Price : 950.00 / Square Feet
Get Best Price
Business Type Manufacturer, Supplier
Certification CE Certified
Size As per Requirement
Colour Choice of Colours
Achieve Ambient 15-20 dB (A)
Design As per Client Requirement
Infilled Material High Density Acoustical Material

Preferred Buyer From

Location Worldwide

The noise test chamber is used for check the noise level. It is a quiet room and is used for a number of different purposes as well. The main functionality of a noise control booth is to eliminate the shop floor noise. The isolation of the noise test booth with acoustic material all around prevents the floor noise from penetrating the enclosure.

We, have a wide range of designs that are used for R&D labs that develop intricate products. These booths primarily function to provide an ambient zone that helps in the assessment of vibration and noise. This also helps in equipping the chamber for improved performances, serving to a high level of accuracies. They are quite useful in automotive, refrigeration and AC industry et al. The booth can also be custom designed to achieve ambient resolution up to 15dB (A). It provides proper fabrication with supply. Site installation can be availed with the quality test as per the requisite. Other industries where this can be used are electric motors, transformers, speaker testing, and compressor manufacturing units.

Read More...


Yes! I am interested


Price : 10,500.00 / Square Meter
Get Best Price
Business Type Manufacturer
Shape Circular Or Rectangular
Size As per Client Requirement
Colour As per Client Requirement
Infilled Material High Density Acoustical Material
Sound Reduction 20-25 dB (A)
Design CAD Drawing of Acoustic Silencer as per Actual Site Condition

Preferred Buyer From

Location Worldwide

The silencers can be installed with catalysts or SCR systems if required by the client. The silencers are usually cylindrical in shape with a circular or oval opening. They are made of a variety of materials which depends to a large extent on the application.

There are two types of engine exhaust silencers which are as follows :

  • Absorptive type silencer : The absorptive engine silencer has sound control levels between 15dB (A) to 25dB (A) (type SM15P and SM25P)
  • Reactive type silencer : The reactive and wave phase shift has a noise control level of 30dB (A) to 50dB (A) (type SM30P, SM40P, SM50P)


Usages For :

  • HVAC systems
  • Cooling towers
  • Generators
  • Industrial fans
  • Outlet and inlets at radiator
Read More...


Yes! I am interested




Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us